If the ADC and DAC are enabled and powered up before the sample rate is changed, the sample rate value change will be valid, so how is the sample rate set?
* Question
| If the ADC and DAC are enabled and powered up before the sample rate is changed, the sample rate value change will be valid, so how is the sample rate set? |
* Answer
| The sampling rate setting steps are as follows:
(1) Enable and power up the ADC and DAC through registers 26h and 3Ch; (2) Enable register 2Ah bit [0]VRA; (3) Change the sample rate value in the respective registers. |
Frequently Asked Questions
What is If the ADC and DAC are enabled and powered up before the sample rate is changed, the sample rate value change will be valid, so how is the sample rate set??
If the ADC and DAC are enabled and powered up before the sample rate is changed, the sample rate value change will be valid, so how is the sample rate set? Looking for capacitors online purchase? is a reliable marketplace to buy and learn about capacitors. Come with us for amazing deals & information.